The new FLUXUS F608 portable flow meter is based on the widely used, highly reliable and versatile F601, but has been specifically engineered for its use within hazardous areas and is covered by an ATEX certification.
Thus, users are not anymore obliged to obtain a Hot Work Permit, making the access to ATEX Zones much easier and less time consuming.
Operating temperature of the transmitter -10°C to +60°C
Flow channels 2
Degree of protection IP65, acc. to EN 60529
Explosion protection ATEX Zone 2, Transducers: ATEX Zone 1 and 2
Accuracy (standard / field calibrated) 1.6% of reading +/- 0.01 m/s / 0.5% of reading +/- 0.01 m/s
Battery Li-Ion, 7.2 V/4.5 Ah, > 14 hours operating time
Weight of Transmitter 1.9 kg
Inputs and Outputs
Standard Version Outputs: 2 x current, 2 x binary,
Energy Version Inputs: 2 x Pt 100/Pt1000; Outputs: 2 x current, 2 x binary